{"id":12257,"date":"2026-09-21T13:38:42","date_gmt":"2026-09-21T10:38:42","guid":{"rendered":"https:\/\/efsan.com\/?p=12257"},"modified":"2026-09-24T14:03:37","modified_gmt":"2026-09-24T11:03:37","slug":"atex-plastic-fan-and-ex-proof-plastic-fan-manufacturer","status":"publish","type":"post","link":"https:\/\/efsan.com\/en\/atex-plastic-fan-and-ex-proof-plastic-fan-manufacturer\/","title":{"rendered":"ATEX Plastic Fan and Ex-proof Plastic Fan Manufacturer"},"content":{"rendered":"<h2 id=\"toc_Antistatik_Ozel_Tasarm_ve_Yuksek_Performansl_Plastik_Radyal\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>Antistatic, Special Design and High Performance Plastic Radial Fans<\/strong><strong>\u00a0<\/strong><\/h2>\n<p><strong><a href=\"https:\/\/en.wikipedia.org\/wiki\/ATEX_directives\" target=\"_blank\" rel=\"noopener\">ATEX<\/a> plastic fan <\/strong>is a special industrial fan solution used in processes where explosive atmosphere is likely to occur and designed by evaluating the mechanical structure of the fan, material properties, electrostatic charging, grounding and other possible ignition sources.<\/p>\n<p>As Efsan Machine <strong><a href=\"https:\/\/efsan.com\/en\/products\/plastic-fans\/\">plastic fan<\/a> its production with a fan engineering approach<\/strong> we realize. Plastic fan not only as a ventilation equipment made of plastic material; <strong>flow rate, pressure, temperature, gas properties, rotor geometry, mechanical safety, sealing and process conditions<\/strong> a designed by evaluating together <strong>industrial radial fan<\/strong> we treat it as.<\/p>\n<p>This approach is even more important in ATEX applications. Because just because the fan motor is ex-proof does not mean that the entire fan automatically meets ATEX requirements. Mechanical or electrostatic ignition sources that may occur in the fan itself should also be evaluated.<\/p>\n<h2 id=\"toc_ATEX_Plastik_Fan_Nedir\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>What is ATEX Plastic Fan?<\/strong><\/h2>\n<p>ATEX plastic fan; Designed for use in hazardous areas where explosive gas, steam or fog atmospheres may be present <strong>it is a plastic radial or centrifugal fan<\/strong>.<\/p>\n<p>It cannot be assumed that a standard plastic fan can be used in an ATEX environment. The following parameters should be evaluated together in fan selection and design:<\/p>\n<ul>\n<li>Zone class<\/li>\n<li>Gas group<\/li>\n<li>Temperature class<\/li>\n<li>Process temperature<\/li>\n<li>Chemical properties of gas or steam<\/li>\n<li>Debi<\/li>\n<li>Pressure<\/li>\n<li>Gas density<\/li>\n<li>Material properties<\/li>\n<li>Electrostatic charge<\/li>\n<li>Grounding<\/li>\n<li>Mechanical operating conditions between rotor and body<\/li>\n<li>Sealing requirements<\/li>\n<\/ul>\n<p>Therefore, an ATEX plastic fan is not a product obtained by simply adding an ex-proof motor on top of a standard plastic fan. The entire fan must be evaluated according to the operating conditions of the process.<\/p>\n<p><img decoding=\"async\" class=\"lazyload alignnone wp-image-12252 size-full\" src=\"https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan.jpg\" data-orig-src=\"https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan.jpg\" alt=\"atex plastic fan\" width=\"1600\" height=\"1200\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%271600%27%20height%3D%271200%27%20viewBox%3D%270%200%201600%201200%27%3E%3Crect%20width%3D%271600%27%20height%3D%271200%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan-200x150.jpg 200w, https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan-300x225.jpg 300w, https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan-400x300.jpg 400w, https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan-600x450.jpg 600w, https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan-768x576.jpg 768w, https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan-800x600.jpg 800w, https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan-1024x768.jpg 1024w, https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan-1200x900.jpg 1200w, https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan-1536x1152.jpg 1536w, https:\/\/efsan.com\/wp-content\/uploads\/2026\/09\/atex-plastik-fan-efsan.jpg 1600w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1600px) 100vw, 1600px\" \/><\/p>\n<blockquote><p>This article may interest you. <a class=\"awb-custom-text-color awb-custom-text-hover-color\" href=\"https:\/\/efsan.com\/en\/industrial-plastic-fan-selection-guide\/\" target=\"_self\">Uses and Process Applications of Industrial Plastic Radial Fans<\/a><\/p><\/blockquote>\n<h2 id=\"toc_Exproof_Motor_Neden_Tek_Basna_Yeterli_Degildir\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>Why Is Ex-Proof Motor Alone Not Enough?<\/strong><\/h2>\n<p>In a system <strong>using an ex-proof motor does not mean that the entire fan is ATEX compatible.<\/strong><\/p>\n<p>In ATEX application, fan body, rotor, shaft, connections, material properties, electrostatic charging, grounding and mechanical working conditions should be evaluated together.<\/p>\n<p>Especially in plastic fans, electrostatic charging is an important design issue. Electrostatic charge may occur on plastic surfaces due to process flow, particles, droplets or other operating conditions.<\/p>\n<p>That&#8217;s why ATEX is in plastic fan design:<\/p>\n<ul>\n<li>Selection of antistatic or conductive materials<\/li>\n<li>Grounding<\/li>\n<li>Rotor and body design<\/li>\n<li>Preventing mechanical friction<\/li>\n<li>Assessment of possible sources of ignition<\/li>\n<\/ul>\n<p>considered together.<\/p>\n<p><strong>Efsan Machinery&#8217;s approach is not only to choose an ex-proof motor, but to evaluate the entire fan in terms of process and ATEX requirements.<\/strong><\/p>\n<h2 id=\"toc_Antistatik_Plastik_Fan_Tasarm\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>Antistatic Plastic Fan Design<\/strong><\/h2>\n<p><strong>Antistatic plastic fan<\/strong>is a fan designed with a suitable material and construction approach to control electrostatic charge in applications with explosive atmosphere.<\/p>\n<p>In these applications, not only the surface properties of the fan are evaluated, but also the entire material and construction.<\/p>\n<p>Efsan Machinery in plastic fan applications, when required by the process <strong>Antistatic material options such as PP-EL and PP-EL-S<\/strong> can evaluate.<\/p>\n<p>Antistatic structure;<\/p>\n<p><strong>material + construction + grounding + process conditions<\/strong><\/p>\n<p>it is evaluated by considering them together.<\/p>\n<h2 id=\"toc_Zone_1_ve_Zone_2_ATEX_Plastik_Fan\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>Zone 1 and Zone 2 ATEX Plastic Fan<\/strong><\/h2>\n<p>ATEX fan selection <strong>Zone 1 and Zone 2<\/strong> its distinction is one of the basic parameters.<\/p>\n<p><strong>Zone 1<\/strong>, refers to areas where an explosive atmosphere of gas, steam or fog may occasionally form during normal operation.<\/p>\n<p><strong>Zone 2<\/strong> on the other hand, it refers to areas where explosive atmosphere is not expected to occur during normal operation, and if it occurs, it is expected to be short-term.<\/p>\n<p>However, an ATEX plastic fan is not selected based solely on the Zone number. <strong>Gas assembly, temperature class, process temperature, gas characteristics and actual operating conditions of the equipment<\/strong> it should also be evaluated.<\/p>\n<p>Therefore, in Zone 1 or Zone 2 applications, the design of the fan must be made based on the relevant process and equipment requirements.<\/p>\n<h2 id=\"toc_Yuksek_Basncl_ve_Yuksek_Debili_ATEX_Plastik_Fan\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>High Pressure and High Flow ATEX Plastic Fan<\/strong><\/h2>\n<p>Efsan Machinery is not only plastic fans for standard ventilation applications <strong>specially designed plastic radial fans with high pressure and high flow rate<\/strong> it also produces.<\/p>\n<p>The performance of a plastic fan is not determined solely by fan diameter or motor power.<\/p>\n<p>Actual operating point;<\/p>\n<p><strong>flow rate + pressure + temperature + gas characteristics + density + speed + system resistance<\/strong><\/p>\n<p>it is determined by evaluating together.<\/p>\n<p>Application specific instead of standard molded fan geometries in corrosive and hazardous processes requiring high pressure or high flow rate:<\/p>\n<ul>\n<li>Rotor geometry<\/li>\n<li>Fan body<\/li>\n<li>Shaft and connection details<\/li>\n<li>Material selection<\/li>\n<li>Sealing solution<\/li>\n<\/ul>\n<p>designable.<\/p>\n<p>This approach in particular <strong>high pressure plastic fan<\/strong>, the <strong>high flow rate plastic fan<\/strong> and it is important in special process fan applications.<\/p>\n<h2 id=\"toc_ATEX_Asit_Fan_ve_Korozif_Gazlar_Icin_Plastik\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>ATEX Acid Fan and Plastic Fan for Corrosive Gases<\/strong><\/h2>\n<p>In addition to the ATEX requirement, plastic fans can be an important solution in processes requiring high corrosion resistance.<\/p>\n<p><strong>Acid fan<\/strong> and in corrosive gas fan applications, suitable materials and construction are evaluated for the following fluids and process gases:<\/p>\n<ul>\n<li>HCl<\/li>\n<li>H\u2082SO\u2084<\/li>\n<li>HNO\u2083<\/li>\n<li>HF<\/li>\n<li>Cl\u2082<\/li>\n<li>NH\u2083<\/li>\n<li>SO\u2082<\/li>\n<li>H\u2082S<\/li>\n<li>Acid gases<\/li>\n<li>Acid vapors<\/li>\n<li>Corrosive gases<\/li>\n<li>Chemical vapors<\/li>\n<li>Toxic process gases<\/li>\n<\/ul>\n<p>However, the fan material is not determined solely by the name of the chemical.<\/p>\n<p><strong>Concentration, temperature, gas composition, flow rate and pressure<\/strong> it creates real working conditions and is evaluated together in material selection.<\/p>\n<p>Therefore, a general approach such as \u201ca single plastic is suitable for all acids\u201d is not correct.<\/p>\n<p><strong>Plastic Fan Material Selection<\/strong><\/p>\n<p>Different plastic and composite material options can be evaluated according to process conditions.<\/p>\n<p>Among them:<\/p>\n<ul>\n<li>PP<\/li>\n<li>PP-EL<\/li>\n<li>PP-EL-S<\/li>\n<li>PVC<\/li>\n<li>PVDF<\/li>\n<li>FRP \/ fiberglass<\/li>\n<\/ul>\n<p>materials such as can be found.<\/p>\n<p>However, material selection is not made solely based on chemical resistance. Mechanical strength, temperature, pressure, gas composition, operating time and ATEX requirements of the fan should also be taken into account.<\/p>\n<p><strong>It is not right to use the same plastic material for every process.<\/strong><\/p>\n<p>Instead of plastic in some applications <strong>FRP or fiberglass fan<\/strong> the solution may be more appropriate. The aim here is not to apply a certain material to every application, but to suit the operating conditions of the fan <strong>to determine materials and construction.<\/strong><\/p>\n<h2 id=\"toc_ATEX_Plastik_Fanlarda_Szdrmazlk\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>Sealing in ATEX Plastic Fans<\/strong><\/h2>\n<p>In systems where chemical gas, acid vapor or hazardous process gases are transported <strong>sealing is one of the important parameters of fan design.<\/strong><\/p>\n<p>Especially:<\/p>\n<ul>\n<li>HCl and other acid gases<\/li>\n<li>Chemical vapors<\/li>\n<li>Corrosive gases<\/li>\n<li>Toxic gases<\/li>\n<li>Scrubber outlets<\/li>\n<li>Ex-proof processes<\/li>\n<\/ul>\n<p>fan body connections and shaft passages should be carefully evaluated.<\/p>\n<p>Construction is developed in Efsan Makina plastic fans according to the sealing level required by the process.<\/p>\n<p>When necessary:<\/p>\n<ul>\n<li>Special shaft sealing<\/li>\n<li>Additional sealing elements<\/li>\n<li>Special body connections<\/li>\n<li>Connection details in accordance with process conditions<\/li>\n<li>Plastic valve solutions suitable for PP valve and process circuit<\/li>\n<\/ul>\n<p>evaluable.<\/p>\n<p>Sealing is therefore not a standard product feature <strong>a fan parameter designed according to the process requirement<\/strong> it is treated as.<\/p>\n<h2 id=\"toc_Plastik_Hava_Klapesi_ve_PP_Vana_Cozumleri\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>Plastic Air Clamp and PP Valve Solutions<\/strong><\/h2>\n<p>In ATEX and corrosive gas systems, the fan should not be evaluated alone.<\/p>\n<p>Depending on the need of the process <strong>plastic air valve, PP valve and other plastic process equipment<\/strong> it can also be evaluated together with the fan system.<\/p>\n<p>These equipment;<\/p>\n<ul>\n<li>Chemical suction lines<\/li>\n<li>Scrubber systems<\/li>\n<li>Acid gas lines<\/li>\n<li>Corrosive air ducts<\/li>\n<li>Wastewater and treatment plants<\/li>\n<li>Chemical processes<\/li>\n<\/ul>\n<p>it can be used in applications such as.<\/p>\n<h2 id=\"toc_ATEX_Plastik_Fan_Nerelerde_Kullanlr\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>Where is ATEX Plastic Fan Used?<\/strong><\/h2>\n<p>ATEX plastic fans, <strong>in processes where the risk of explosive atmosphere and corrosion resistance are important at the same time<\/strong> available.<\/p>\n<p>Major applications:<\/p>\n<ul>\n<li>Chemical plants<\/li>\n<li>Petrochemical plants<\/li>\n<li>Acid processes<\/li>\n<li>Pickling \/ pickling lines<\/li>\n<li>Galvanizing plants<\/li>\n<li>Scrubber systems<\/li>\n<li>Wastewater treatment plants<\/li>\n<li>Industrial treatment plants<\/li>\n<li>Battery and battery production facilities<\/li>\n<li>Paint and coating facilities<\/li>\n<li>Pharmaceutical and chemical processes<\/li>\n<li>Chemical storage areas<\/li>\n<li>Processes with flammable gas<\/li>\n<li>Hazardous process gas suction systems<\/li>\n<li>Corrosive gas and chemical vapor absorption systems<\/li>\n<\/ul>\n<p>Especially <strong>ATEX plastic fan, ex-proof plastic fan, antistatic plastic fan and corrosive gas fan<\/strong> in applications where the need is in the same system, it becomes important to design the fan on a process basis.<\/p>\n<h2 id=\"toc_Efsan_Makina_ATEX_Plastik_Fan_Uretim_Yaklasm\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>Efsan Machinery ATEX Plastic Fan Production Approach<\/strong><\/h2>\n<p>Efsan Machine; <strong>ATEX plastic fan, ex-proof plastic fan, antistatic plastic fan, high pressure plastic fan, high flow rate plastic fan and specially designed plastic radial fan<\/strong> develops solutions.<\/p>\n<p>The basic approach here is to consider plastic material as a production material only <strong>it is to evaluate as part of fan engineering.<\/strong><\/p>\n<p>In a plastic fan design:<\/p>\n<p><strong>Process \u2192 flow rate \u2192 pressure \u2192 temperature \u2192 gas properties \u2192 material \u2192 rotor \u2192 mechanical safety \u2192 sealing \u2192 ATEX requirements<\/strong><\/p>\n<p>evaluated together.<\/p>\n<p>Thanks to this approach, instead of a standard plastic fan, it is suitable for the actual working conditions of the process <strong>special design industrial radial fan<\/strong> developable.<\/p>\n<p><strong>Plastic material expertise and fan engineering are not the same thing.<\/strong><\/p>\n<p>Efsan Machinery carries out plastic fan production with an industrial fan design, rotor production, balancing, mechanical safety, performance and process engineering approach.<\/p>\n<h2 id=\"toc_ATEX_Plastik_Fan_Hakknda_Sk_Sorulan_Sorular\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>Frequently Asked Questions About ATEX Plastic Fan<\/strong><\/h2>\n<p><strong>What is an ATEX plastic fan?<\/strong><\/p>\n<p>ATEX plastic fan is a plastic radial fan designed by evaluating the material, mechanical structure, electrostatic properties, grounding and possible ignition sources of the fan for use in areas where there is a risk of explosive atmosphere.<\/p>\n<p><strong>Can a plastic fan be used in an ATEX environment?<\/strong><\/p>\n<p>It can be used if appropriate design and relevant requirements are met. It should not be assumed that a standard plastic fan can be used in an ATEX environment. Zone, gas group, temperature class, material, electrostatic properties and mechanical design should be evaluated together.<\/p>\n<p><strong>Does an ex-proof motor plastic fan make an ATEX fan?<\/strong><\/p>\n<p>No. Ex-proof motor alone does not mean that the entire fan meets ATEX requirements. The rotor, body, material, mechanical safety, electrostatic charging and grounding properties of the fan should also be evaluated.<\/p>\n<p><strong>Why is antistatic plastic fan used?<\/strong><\/p>\n<p>It is important to control electrostatic charges that may occur on plastic surfaces in explosive atmospheres. Therefore, suitable antistatic or conductive material and correct grounding are important parts of the fan design.<\/p>\n<p><strong>Can ATEX plastic fan be used in Zone 1\u2019?<\/strong><\/p>\n<p>The fan to be used in Zone 1 applications must comply with the relevant ATEX requirements and the equipment category, gas group and temperature class of the application. The fan should be evaluated specifically according to the application conditions.<\/p>\n<p><strong>Can ATEX plastic fan be used in Zone 2\u2019?<\/strong><\/p>\n<p>Plastic fan solutions can be used for Zone 2 applications when appropriate design and relevant ATEX requirements are met.<\/p>\n<p><strong>Can a plastic fan be used for HCl?<\/strong><\/p>\n<p>When appropriate plastic materials and process conditions are determined, a plastic fan can be used to transport HCl-containing gases and vapors. Especially <strong>HCl concentration and temperature<\/strong> they are the determining parameters in material selection.<\/p>\n<p><strong>Can a high pressure plastic fan be produced?<\/strong><\/p>\n<p>Yes. Plastic radial fans can be produced according to processes requiring high pressure with a special rotor and body design according to the actual working point and process conditions.<\/p>\n<h2 id=\"toc_Sonuc\" class=\"fusion-responsive-typography-calculated\" data-fontsize=\"42\" data-lineheight=\"54.6px\"><strong>Conclusion<\/strong><\/h2>\n<p><strong>ATEX plastic fan<\/strong>, it is not a standard fan consisting only of a plastic body and ex-proof motor.<\/p>\n<p>For the right fan solution <strong>process conditions, flow rate, pressure, temperature, gas characteristics, zone, material, electrostatic charging, mechanical safety and sealing<\/strong> should be considered together.<\/p>\n<p><a href=\"https:\/\/efsan.com\/en\/\">Efsan Machine<\/a> as this approach <strong>custom design industrial fan engineering<\/strong> combines with; We develop ATEX plastic fan and plastic radial fan solutions for chemical, corrosive, flammable and explosive processes.<\/p>\n<blockquote><p>With our engineering team, we communicate your gas density, flow rate (m\u00b3\/h), pressure (Pa) and ambient temperature values in your projects <a href=\"https:\/\/efsan.com\/en\/contact\/\">communication<\/a> oo ahead. Let&#8217;s project your Efsan radial fan selection together, which has the right curve, is fully regulation compatible and energy efficient.<\/p><\/blockquote>\n","protected":false},"excerpt":{"rendered":"<p>Antistatic, Special Design and High Performance Plastic Radial Fans\u00a0 ATEX  [&#8230;]<\/p>\n","protected":false},"author":4,"featured_media":12249,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[445],"tags":[],"class_list":["post-12257","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/efsan.com\/en\/wp-json\/wp\/v2\/posts\/12257","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/efsan.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/efsan.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/efsan.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/efsan.com\/en\/wp-json\/wp\/v2\/comments?post=12257"}],"version-history":[{"count":3,"href":"https:\/\/efsan.com\/en\/wp-json\/wp\/v2\/posts\/12257\/revisions"}],"predecessor-version":[{"id":12262,"href":"https:\/\/efsan.com\/en\/wp-json\/wp\/v2\/posts\/12257\/revisions\/12262"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/efsan.com\/en\/wp-json\/wp\/v2\/media\/12249"}],"wp:attachment":[{"href":"https:\/\/efsan.com\/en\/wp-json\/wp\/v2\/media?parent=12257"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/efsan.com\/en\/wp-json\/wp\/v2\/categories?post=12257"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/efsan.com\/en\/wp-json\/wp\/v2\/tags?post=12257"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}